Tools & Resources > Study Reports & Data Analysis

Study Reports & Data Analysis

Getting the most out of your PathHunter study report

PathHunter Primary Study Data Reports

Primary Study results are delivered as two separate data files and include:

1. Study Report - A PDF file containing a project summary, description of the assay protocol, control agonist dose response curves for each target (where applicable), and data matrix (view primary sample report).

2. Data Report – An Excel spreadsheet file containing duplicate raw data values, average % activity or % inhibition of all compound/target interactions and summary tables.

Sample Primary Study Report Data Matrix

Sample Primary Study Report Data Matrix


PathHunter EC50/IC50 Determination Study Reports (10-point dose response curves)

PathHunter EC50/IC50 Determination Study reports are delivered as two separate data files and include:


1. Study Report - A PDF file containing a project summary, description of the assay protocol, control agonist dose response curves for each target (where applicable), data matrix which provides EC50/IC50 values for each compound against the tested targets, curve images which display the data points and the best fit curve for each EC50/IC50 determination (view PathHunter EC50/IC50 sample report).

2. Data Report - A spreadsheet file containing the raw data values reported from duplicate EC50/IC50 determinations, which can be easily imported into most data management and visualization tools.


Sample Curve Images

Sample Curve Images


Data Analysis & Intrepretation 

Definitions

Percent Activity/Inhibition

The results for single concentration (primary screen) for tested compound(s) are reported in your study report and spreadsheets as '% Activity' or '% Inhibition' and are calculated in the following manner:

% Activity(Agonist Mode) =
100% x
[
Mean RLU (test sample)- Mean RLU(vehicle control)
]

Mean MAX RLU (control ligand)- Mean RLU (vehicle control)


test sample = client supplied compound
vehicle control = DMSO (0% activity)
control ligand = control compound (100% activity)

% Inhibition (Antagonist mode) = 100% x
[
1- 
Mean RLU (test sample)- Mean RLU(vehicle control)
]

Mean MAX RLU (control ligand)- Mean RLU (vehicle control)

test sample = client supplied compound
vehicle control = DMSO (0% activity)
EC80 control = control compound (80% activity)

Dose Response Curve (EC50/IC50)

The results for 10-point dose response curve compound/target interactions are reported in the study report and spreadsheets as EC50/IC50, which are values derived using the Hill equation:

hill equation


Additional Follow Up Services

Pathunter EC50/IC50 Determination

An ideal follow-up service for Primary Screening. Generate an EC50/IC50 value of compound/target interactions observed in initial PathHunter study data. PathHunter EC50/IC50 determinations are performed as 10-point dose-response curves (in duplicate) and can be requested for any target, making it an ideal tool for primary study follow-up.
  • 10-point dose-response curve performed in duplicate
  • Consistent & reproducible results
  • Can be performed against any of our assays